Maintenance Object Repair Procedures
555-233-123
10-778
Issue 4 May 2002
Expansion Interface LED Usage
The EI circuit pack has the standard red, green, and yellow LEDs. The red and
green LEDs have the traditional use, where red means some alarm condition and
green indicates maintenance testing in progress. The yellow LED is used to
provide useful visual status information. The state of the yellow LED is very
important when executing the EI Manual Loop Back Procedure previously
described.
Upon power-up, the TN776 red LED comes on and off, followed by the yellow
LED coming on solid. The TN570 red and green LEDs comes on and off. The
yellow LED remains off.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the Expansion Interface Reset Test, for
example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Expansion Interface Reset Test (#336)
D
Expansion Interface Fiber Out-of-Frame Query
Test (#238)
X
X
ND
Expansion Interface Lightwave Transceiver
Interface Loop Around Test (#242)
X
D
Expansion Interface Control Channel Test (#316)
X
X
ND
Expansion Interface Neighbor Query Test (#237)
X
X
ND
Expansion Interface Local Loop Around Test
(#240)
X
X
ND
Expansion Interface 2-Way Transmission Test
(#241)
X
X
ND
TN570 Expansion Interface Packet Interface Test
(#589)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...