HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-905
555-233-123
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates run only if the station is
in-service.
Table 10-329.
TEST #60 Hybrid Line Lamp Updates Test
Error
Code
Test
Result
Description/Recommendation
1
ABORT
A request for a remote station lamp update aborted even
though all internal resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for
this port. If this error type is present, release the port via
release port PCSSpp or the release station extension,
and then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum
of 5 times.
2
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a maximum of
5 times.
3
ABORT
The station is in a ready for service or an out of service state.
This may be due to wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
PCSSpp to determine the station extension number of the
port. Use status station to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the “Status
Commands” section in Chapter 10, “Maintenance Commands
and Trouble-Clearing Aids” for a full description of all possible
states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...