Maintenance Object Repair Procedures
555-233-123
10-1954
Issue 4 May 2002
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine if the
VAL circuit pack is congested.
Normal call handling resumes when the VAL circuit pack has recovered from
congestion.
FAIL
Circuit pack has detected a failure of the Packet Interface Test
(#598).
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the test continues to fail, replace the circuit pack.
PASS
The Packet Interface Test (#598) passed.
If:
Then:
Used buffers are, or are nearly,
exhausted,
The test fails.
The test fails,
The switch alarms, and announcements can fail.
Table 10-699.
TEST #600 Congestion Query Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the problem persists, replace the circuit pack.
Continued on next page
Table 10-698.
TEST #598 Packet Interface Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...