Maintenance Object Repair Procedures
555-233-123
10-1600
Issue 4 May 2002
Notes:
a. Error Type 13: indicates that the link went down. The link may have gone
down or never come up. Enter command status sys-link location and
check the value of the field
Faulted Path
. If the value is
default
, then
the link never came up. If the value is
present
, then the link came up and
went down.
Follow the Common Procedure described above. Wait for 3 min before
checking the link state. Repeat the procedure until there are no problems
with the components.
b. Error Type 257: indicates that the link has experienced uplink flow control.
Manifest effect of this error is that the end-point may be hyperactive. The
system link is alarmed if 4 or more errors of this type are detected within 10
minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
c. Error Type 513: indicates that the link has experienced downlink flow
control. Manifest effect of this error is that some information packets from
the packet interface board have been lost. The link is reset on first
occurrence, hence, Error 1025 will also be logged. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
d. Error Type 772: indicates that the link experienced a temporary disconnect
due to excessive resets or state transitions. The effect of this error is that
the link is taken down and then brought up again. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
e. Error Type 1025: This error indicates that the link has been reset. Manifest
effect of this error is that information packets queued at the time of reset
are been lost. The system link is alarmed if 20 or more errors of this type
are detected within 10 minutes.
1537 (g)
WARNING
OFF
test sys-link PCSSpp l cl
1793 (h)
WARNING
OFF
test sys-link PCSSpp l cl
2049 (i)
WARNING
OFF
test sys-link PCSSpp l cl
Table 10-590.
SYS-LINK Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...