Maintenance Object Repair Procedures
555-233-123
10-464
Issue 4 May 2002
2056
ABORT
An error occurred while trying to obtain results from the TN771
circuit pack.
1. Test the TN771 circuit packs.
FAIL
Measured transmission performance was in the unacceptable
range as administered on the trunk group form. Retrieve a
measurement report via the list testcalls command. Make
sure that ATMS thresholds are set properly on page 4 of the
trunk group form. Besides the facility, test failures can be
caused by faulty test lines or switch paths. If the measurements
point to a facility problem, report the results to the trunk vendor.
8000
FAIL
Measured transmission performance was in the marginal range
as administered on the trunk group form. This generally means
that the trunk is usable but has an undesirable amount of noise
or loss. If the user does not report unacceptable effects, it may
not be necessary to take any action. Retrieve a measurement
report via the list testcalls command. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group form.
Table 10-170.
TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...