
Maintenance Object Repair Procedures
555-233-123
10-494
Issue 4 May 2002
40
41
2000
2003
2004
FAIL
Error Codes 40 and 41: Remote Maintenance Looparound Test
failed because data was corrupted.
Error Codes 2000-2004: Remote Maintenance Looparound Test
failed because data was lost.
Test cannot indicate which DATA-CHL is defective.
1. Check dial plan to ensure data channel extensions are set up
as local extensions rather than remote or UDP extensions.
2. Determine if links exist on DATA-CHLs (status link).
3. Execute tests #110 and #111 in the Short Test Sequence for
the target DATA-CHL to determine which actions to take,
based on the results below.
a. Both Test results are PASS: Arbitrarily chosen DATA-CHL
is probably defective.
1. Run Short Test Sequence for each
DATA-CHL not in use.
2. Note the test results for Tests #110 and #111
for each DATA-CHL.
3. Remove DATA-CHLs (remove data-module
ext) for which the results of Tests #110 and
#111 were both FAIL.
4. Replace the Netcon or NetPkt circuit pack at
earliest convenience.
b. Only one test result is FAIL for any other DATA-CHLs not
in use: TDM Bus is probably defective.
c. Test #110 result is FAIL and Test #111 result is PASS (for
target DATA-CHL): Either the RDM Bus or Tone-Clock
circuit pack is defective.
1. Check for TDM bus alarms or errors
(TDM-BUS) and/or Tone-Clock circuit pack
alarms or errors (TONE-BD, TONE-PT, and
TDM-CLK).
2. If there are no errors or alarms, the target
DATA-CHL, or Netcon or NetPkt circuit pack
are probably defective: refer to steps in 3a
above.
3. If there are errors or alarms, refer to
Maintenance documentation to clear the
alarms and errors.
4. Repeat the test.
Table 10-181.
TEST #109 Data Channel Remote Maintenance Loop Around
Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...