Maintenance Object Repair Procedures
555-233-123
10-926
Issue 4 May 2002
Table 10-337.
TEST #53 SAKI Sanity Test
Error
Code
Test
Result
Description/Recommendation
None
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1015
ABORT
Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2803
ABORT
It is necessary to reset the board.
1. Use the change ip-interfaces form to disable the
Media Processor IP interface.
2. Execute the command again.
1
FAIL
The circuit pack failed to reset.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
2,
2000
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the short test sequence.
Any
NO
BOARD
This is normal if the test is being done when (a) the board is not
physically in the system or (b) the system is booting up.
Otherwise, there is some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...