Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-2
Issue 4 May 2002
If the board that contains the access endpoint is not inserted in the system, the
following message appears:
Board not inserted
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
busyout board
This command will busyout each maintenance object on the specified board.
Help Messages
If the system technician presses
HELP
after entering “busyout board,” the following
message appears:
Enter 5 character board number
Error Messages
If the format of the board location is incorrect, the following error message
appears:
Port/Board invalid
If the EPN on which the board resides is not available, the following message
appears:
EPN is not available
If a board is not inserted in the specified location, the following message appears:
Board not assigned
If the specified board does not have any maintenance objects associated with it,
the following message appears:
No MO in this board
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...