ANL-16-L (16-Port Neon Analog Line)
Issue 4 May 2002
10-79
555-233-123
1008
ABORT
Could not allocate a ringing circuit. Either all the ringing
circuits are in use or the ringing generator is defective or it is
not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, look for RING-GEN errors in
the Error Log. If an ABORT 1008 occurs for this test on
other circuit packs as well, then the ringing generator may
be defective or is not wired correctly (see errors for
RING-GEN). If it doesn’t occur on other ports, then all
four ring phases are in use.
1018
ABORT
The test has been disabled via administration. The default for
the 'Test' field on the 'Station' form is 'y'; thus, you may want
to determine why this field has been set to 'n' on this station
(this may be due to the brief ringing disturbance that this test
may cause).
1. To enable the test for the particular analog station being
tested, enter change station extension and set the
‘Test?’ field on the station from 'n' to 'y.'
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-29. TEST #48 Station Present Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...