
MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1109
555-233-123
This test attempts to allocate a Network Control Channel, Modem Pool Port, and
other internal resources. If any of these allocation attempts fail, the test cannot be
completed and a specific abort error is reported.
Table 10-417.
TEST #98 Modem Pool Conversion Resource Loop Around Test
Error
Code
Test
Result
Description/Recommendation
NONE
ABORT
Internal System Error.
1. Wait one-minute and try the test again.
5000
ABORT
System resources needed to complete the test could not be
allocated for the digital section of the Modem Pool conversion
resource. Ordinarily, this means the conversion resource or
other hardware used during the test was in use.
1. Wait one minute and attempt the test again.
2. If it is absolutely necessary to test the conversion
resource, the call must be dropped by issuing a busyout
port PCSS command against the conversion resource.
Issue the release port PCSS command. The busyout and
release of the port drop any existing calls on that port.
3. Run the test again.
4. If the same error occurs while the conversion resource is
idle, busyout and release both Modem Pool conversion
resources on the TN758 Pooled Modem circuit pack
containing the conversion resource under test. This action
drops any existing calls on that circuit pack.
5. If the test continues to abort, replace the Pooled Modem
circuit pack and retest.
6. If the test continues to abort with this error code after
circuit pack replacement, escalate the problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...