Maintenance Object Repair Procedures
555-233-123
10-308
Issue 4 May 2002
1187
ABORT
The circuit pack, port or station may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via the release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for BRI-SET only, then release the
circuit pack via the release port PPCSS command and
run the test again. If the error is present for both
BRI-BD and BRI-PORT, then release the circuit pack
via the release board PPCSS command and run the
test again.
NOTE:
When you release the circuit pack, you
release all ports associated with it. If certain
ports still need to be busied out, use the
release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5
times.
5. If the test continues to abort, escalate the problem.
Table 10-122.
TEST #626 Signaling Link Status Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...