BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-311
555-233-123
1187
ABORT
The circuit pack, port or station may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for both BRI-BD and BRI-PORT, then
release the circuit pack via the release board PPCSS
command and run the test again. If the error is present
for BRI-SET only, then release the circuit pack via the
release port PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you
release all ports associated with it. If certain
ports still need to be busied out, use the
release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5
times.
2012
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2068
ABORT
The endpoint has rejected the switch sent application
message. This indicates that the endpoint does not support
the ISDN-BRI Management and Maintenance Procedure for
Loop Back Testing.
1. Use the change station extension command and
change the MIMs Supported field to “no.”
Table 10-123.
TEST #627 BRI Remote Loop Back — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...