POWER (Battery & Battery Charger) for AC-Powered
Systems
Issue 4 May 2002
10-1339
555-233-123
5. Check the battery dates and replace the batteries if they are more than four
years old or if a POWER alarm is present.
NOTE:
If any defective batteries are found, replace all of them. Batteries are
ordered in sets of three and should be replaced as such.
6. If no defective batteries are found, replace the entire charger.
7. Close the cover and secure it with the screw.
8. Reconnect the cord and move the power switch to ON.
Hardware Error Log Entries and Test to Clear
Values
a. Where P is an appropriate port network number determined via the Port
field from the Alarm or Error Log.
Battery & Battery Charger Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment P sh r 1
1
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 8)
MINOR
ON
test environment P sh r 1
257
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 4)
MINOR
ON
test environment P sh r 1
769
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 2)
MINOR
ON
test environment P sh r 1
3840
1005 or
1028
Battery & Battery
Charger Query Test
(#5)
ON
test environment P sh r 1
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...