IPMEDPRO (IP Media Processor Circuit Pack)
Issue 4 May 2002
10-921
555-233-123
Notes:
a. Error Type 1 - indicates that the circuit pack has been removed from the
system or is not fully administered. The alarm is logged about 15 minutes
after the circuit pack has been removed, or 11-minutes after the
SAKI
Test
(#53) fails.
To be fully administered, a IPMEDPRO circuit pack must meet all of these
4 conditions:
1. Have an entry in the circuit pack form (change circuit pack)
2. Have the MedPro ip address administered (change node-names)
3. Be enabled (change ip-interface)
4. Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit pack form and either of the
other two conditions are not met, a MINOR alarm is logged. To resolve the
error:
1. Make sure all conditions for administration are met and that a
functioning MedPro circuit pack is inserted in the correct slot
OR
2. Completely remove the IPMEDPRO from the system using the
following steps:
a. Remove the administered
IP-Interface
associated with the
circuit pack.
b. Physically remove the circuit pack from the slot.
c. Execute the remove medpro UUCSS and change circuit
pack UUCSS commands.
b. Error Type 18 -The IPMEDPRO Interface circuit pack has been busied out
by a busyout board UUCSS command.
1. Release the circuit pack (release board UUCSS).
c. Error Type 23 -The IPMEDPRO circuit pack is not completely
administered. To be fully administered, an IPMEDPRO circuit pack must
meet all of these 4 conditions:
1. Have an entry in the circuit plan (change circuit pack)
2. Have the IPMEDPRO IP address administered (change
node-names)
3. Be enabled (change ip-interface)
4. Be physically inserted into the correct slot.
A DS1 (IPMEDPRO, MEDPRO, MAPD, UDS1-BD and DS1-BD) differs
from most circuit packs in that inserting the circuit pack into the switch is
not enough to make the board usable. It must also be administered.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...