PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1195
555-233-123
7
FAIL
Conference test failed on the primary information channel. In
some cases, user may not notice disruption in service. In
extreme cases, conferencing feature may not work at all.
14
FAIL
The primary information channel is not transmitting properly.
User impact may range from noticing nothing to not being
able to use this port.
15
FAIL
The control channel between the processor and Digital Line
circuit pack is not transmitting properly. This can cause a wide
range of effects. The user may notice nothing or the port may
be totally unusable. This could also disrupt other users.
1. Run circuit pack tests to check the Tone Generator and
the Tone Detector circuit packs using the test board
UUCSS short command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the
Digital Line circuit pack.
16
FAIL
The secondary information is not transmitting properly. This
can cause a wide range of effects. The user may notice
nothing or the port may be totally unusable.
1. To be sure that this is not an intermittent problem, repeat
this test up to a maximum of 10 times to make sure it
continues to pass.
2. If complaints still exist (poor data transmission), examine
the data module, connections, and wiring.
PASS
Information and Control Channel Local Loop Test passed. All
channels are transmitting properly.
Table 10-446.
TEST #13 Information and Control Channel Local Loop Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...