Maintenance Object Repair Procedures
555-233-123
10-818
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate tests in the order presented when inspecting errors in the system. By
clearing error codes associated with the Battery & Battery Charger Query Test,
you may also clear errors generated from other tests in the testing sequence.
Table 10-298.
Hardware Error Log Entries and Test to Clear Values
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence. If all tests pass, run the Long Test Sequence.
0
Any
Any
Any
test environment UU r2 or 6
1 or 5
Any
External Device
Alarm Test (#120)
MAJOR
MINOR
2
2
One port generates a MAJOR alarm; the other port generates a MINOR alarm.
OFF
test environment UU r 2 or 6
Multicarrier Cabinet Tests
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
OLS Query Test (Carrier E) (#127) (c)
X
X
ND
OLS Query Test (Carrier D) (#127) (c)
X
X
ND
OLS Query Test (Carrier A) (#127) (c)
X
X
ND
OLS Query Test (Carrier B) (#127) (c)
X
X
ND
OLS Query Test (Carrier C) (#127) (c)
X
X
ND
Emergency Transfer Query Test (#124) (d)
X
X
ND
Cabinet Sensors Query Test (#122) (e)
X
X
ND
External Device Alarm Test (MAJOR port) (#120)
X
X
ND
External Device Alarm Test (MINOR port) (#120)
X
X
ND
Analog Ring Generator Initialization Test (#117) (f)
X
X
ND
Analog Ring Generator Query Test (#118) (f)
X
X
ND
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...