change system-parameters maintenance
Issue 4 May 2002
8-35
555-233-123
Output
The following output example shows a display of the change
system-parameters maintenance command.
Field descriptions (page 1)
Operations Support Parameters
Product
Identification
Identifies switch to an Operations Support System (OSS):
10-digit number starting with 1.
First OSS
Telephone
Number
Switch reports alarms first to the First OSS telephone number
(for example, INADS or Trouble Tracker). The number must be
obtained from the National Customer Support Center (NCSC) or
the TSC. (# and * are not allowed in the telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the first OSS.
(y)
Second OSS
Telephone
Number
The switch reports alarms secondly to the second OSS
telephone number. For example, INADS or DEFINITY SNMP.
The number must be obtained from the National Customer
Support Center (NCSC) or the TSC. (# and * are not allowed in
the telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the second
OSS. (n)
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Endpoint: 5551212 Abbrev Alarm Report? y
Second OSS Endpoint: 5551213 Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y Suspension Threshold: 5_
Restart Notification? y
Test Remote Access Port? n
CPE Alarm Activation Level: none
Packet Bus Activated? n
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 22: 00 Stop Time: 04: 00
Daily Maintenance: daily Save Translation: daily
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no EXP-LINK Interchange: no
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...