Maintenance Object Repair Procedures
555-233-123
10-1112
Issue 4 May 2002
5013
FAIL
The Modem Pool Port did not respond with an on-hook
message when the connection to the Data Channel was
broken, indicating a likely problem with the TN758 Pooled
Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014
ABORT
The Network Control Channel allocated for this test did not
respond correctly to the setup message sent to it after the
connection was established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack
using the test data-module command (refer to the
DATA-CHL maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the
problem.
5015
ABORT
Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
Table 10-417.
TEST #98 Modem Pool Conversion Resource Loop Around Test
— Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...