Maintenance Object Repair Procedures
555-233-123
10-564
Issue 4 May 2002
Demand Download Actions
1. Busyout/Release Command
A maintenance demand busyout/release request for a station will cause the
terminal to be downloaded regardless of its previous download status.
2. Feature Access Code
A Refresh Terminal Parameters Feature Access Code can be used to
request a terminal download action. When this code is followed by a “#”,
the programmable parameters for the current terminal are downloaded
when the terminal goes on hook. When this code is followed by an
extension, the programmable parameters for the specified station are
downloaded.
This Refresh Terminal Parameters Feature Access Code is assigned on
the second page of the “feature-access-codes” screen.
A confirmation is returned if the download request is accepted. A busy tone
is returned if the request is made from a different station when the target
station is off-hook.
The first three green call appearance LEDs on the 84xx 603x terminal will
be turned on for three seconds if the station was successfully downloaded
as a result of an entry of a Refresh Terminal Parameters Facility Access
Code. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or demand
download actions. As described below, the “status station” and “status
attendant” screens can be used to check the download status of a
specified terminal.
Status of Parameter Downloads
The “status station” and “status attendant” screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the Download Status field.
The possible download states are:
Table 10-208.
Terminal Download Status
Status
Terminal Down Load State
Complete
Terminal successfully downloaded sometime in the past.
Pending
System waiting to download the terminal. This may require the
execution of a background periodic test which could take more than
an hour. A demand download as described above may also be
used to initiate an immediate download.
Not Applicable
Not a programmable terminal.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...