Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-370
Issue 4 May 2002
status isdn-testcall
The status isdn-testcall command displays the progress of an outgoing
ISDN-PRI test call. The status form displays the tested ISDN-PRI B-channel port
number, bit error rate, number of bits transmitted, block error rate, number of
blocks transmitted, start time, duration specified, duration of test call and reason
of termination.
Feature Interactions
If the bit error rate or block error rate is greater than zero, the ISDN-PRI trunk may
be in trouble. The statistical information displayed on the terminal may deactivate
the ISDN trunk. This is subjective because the ISDN trunk may be used for data
or voice. If the trunk is used for data and the rates are high, the trunk should be
deactivated. If the trunk is used for voice, the trunk may not be deactivated. Also,
high rates be at risk for some type of power hit.
Output
The following output example is a display of status idsn-testcall 80/1.
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
status
isdn-testcall
group
number
group
member
number
print
administered number associated
with each trunk group.
administered number identifying a
particular trunk within a trunk
group.
Report prints to SAT-linked printer.
Examples:
status isdn-testcall 80/1
status isdn-testcall 78/1 print
init
inads
craft
none
see below
status isdn-testcall 80/1 Page 1 of 1 SPE A
ISDN TESTCALL STATUS
Bit Number Block Number Duration Reason
Error Of Error Of Start Duration Of Of
Port Rate Bits Rate Blocks Time Specified Test Termination
1B1401 0EE0 4EE7 0EE0 6EE2 25/12:36 120 100 in progress
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...