Maintenance Object Repair Procedures
555-233-123
10-760
Issue 4 May 2002
7. If all tests pass and the alarm does not resolve, retest
(test tone UUCSS long clear).
8. If the test passes, terminate the repair process. If it fails,
replace the circuit pack at the customer’s convenience.
Follow the procedures in TONE-BD.
9. If the board is duplicated, switch to the standby side (set
tone).
10. Test the alarmed board (test tone UUCSS long). This
resets the board and is required to reload on-board RAM
associated with the TN2182’s DSPs.
11. If all tests pass and the alarm does not resolve, retest with
test tone UUCSS long clear.
12. If the test passes, terminate the repair process. If it fails,
replace the board. Follow the procedures in TONE-BD.
PASS
The ETR Port has passed the sanity inquiry.
Table 10-286.
TEST #43 Tone Detector Audit/Update Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...