OPS-LINE (DS1 OPS Line)
Issue 4 May 2002
10-1173
555-233-123
1004
ABORT
The port has been seized by a user for a valid call. Use
status station or status trunk command to determine
when the port is available for testing.
1. Retry the command at one-minute intervals a
maximum of 5 times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1018
ABORT
The test was disabled via translation.
1. You may want to determine why the test has been
disabled before you enable it.
2. To enable the test for the particular analog station
being tested, enter the ’change station extension’
command, and then change the ’Test’ field on the
’Station’ form from ’n’ to ’y.’
1020
ABORT
The test did not run due to an already existing error on the
specific port or due to a more general error on the circuit
pack.
1. Examine the error log for existing errors against this
port or the circuit pack and attempt to diagnose the
already existing error. (Error code 1793 indicates a
problem with the DS1 interface board, and any
problems on the associated DS1-BD or UDS1-BD
should be resolved first.)
2000
ABORT
The test was aborted because response to the test was not
received within the allowable time period.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test aborts with error code 2000 again, run short
test sequence on the associated DS1-BD or
UDS1-BD. If tests 138 through 145 on the associated
DS1-BD or UDS1-BD are also aborting with error code
2000, hyperactivity on the board or facility is indicated.
In this case, the hyperactivity problem should be dealt
with first.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of 5 times.
Table 10-442.
TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...