Maintenance Object Repair Procedures
555-233-123
10-1220
Issue 4 May 2002
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Wait 4 minutes and then check the Error Log for any new
occurrences of Errors Type 3073.
If there are no occurrences of this error, both sides of the ISDN
connection agree on the service state, and the negotiation
succeeded. If there is a new occurrence of Error Type 3073,
the negotiation failed (that is, the far-end terminal adapter
twice failed to respond within the mandatory two minute
window). This switch automatically retries approximately every
15 minutes. If the port was initially in the INS (in-service) state,
it is now be placed into the MTC/FE (maintenance, far-end
problem) state (refer to the “Service States” section, which
precedes the PE-BCHL “Hardware Error Log Entries and Test
to Clear Values” table). Incoming calls are accepted, but no
outgoing calls are originated from this port. If an incoming call
is presented, another Service State Audit is immediately
performed in an attempt to bring the PRI Endpoint Port to the
proper state.
Table 10-456.
TEST #256 Service State Audit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...