PI-LINK (Processor Interface Link)
Issue 4 May 2002
10-1231
555-233-123
NOTE:
When an ISDN-PRI link is busied out via a system technician command, the
associated B-channels (ISDN-TRK) are moved to the maintenance and/or
far-end state. As a result, stable calls are NOT dropped, but the trunks are
removed from the trunk hunt group to prevent them from being selected for
outgoing calls. See ISDN-TRK Maintenance documentation.
Up to two Processor Interface circuit packs can be active on the same carrier in
the system. Thus, there can be a maximum of eight Processor Interface links in
service at any one time. If an error or alarm is detected by PI-LINK that can be
associated with a physical port on the Processor Interface circuit pack, then the
Processor Interface Port MO is alarmed, which indicates a defective port on the
circuit pack. Refer to the PI-PT (Processor Interface Port) Maintenance
documentation for details.
It is useful to use the status processor-channel channel-no command when
troubleshooting the PI-LINK. A processor channel corresponds to a processor
application (also called a session) and more than one may be using the same
physical link (only for X.25 links). The relevant field of the status screen is the
“channel status:” which can be in 1 of 7 different states (see the following table).
State 6 is normal state for the processor channel for X.25 links and state 10 is
normal state for ISDN links. States 9 and 10 are only applicable to ISDN links.
States
Description
1
Incorrect translations or channel not assigned.
3
Attempting to reset the channel but no response from the other end. Getting
stuck in this state may be caused by hardware problems, a DS1
synchronization problem or a DCE/DTE conflict in the
Communication-Interface Link Form (one end of the link must be DCE and
the other must be DTE).
4
The other end acknowledged the channel reset (the two ends are physically
connected) but a processor channel connection has not occurred yet.
Getting stuck in this state may indicate that translations are incorrect, such
as remote processor channel mismatch. To recover from this situation,
execute the busyout link lnk-no and release link lnk-no commands. If
this is unsuccessful, then use the reset interface command (note that this
is a destructive command that tears down all four links). This problem may
also be caused by a noisy link or DS1 synchronization problems.
6
This is the normal state of the channel. The link is in the data transfer state
which means that the application is able to send data over the link.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...