DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-665
555-233-123
2000
ABORT
Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is
out of service and one or more of the following symptoms may
be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. busyout and release have no affect on the test results.
4. list config shows that the circuit pack and the ports are
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will try
to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the DS1 interface
circuit pack is restored to normal operation. All of the
trunks for the DS1 interface circuit pack are then returned
to the in service state. Hyperactivity is often caused by the
associated facility. In such a case, faults (such as slips,
misframes, or blue alarms) would be entered in the error
log. In addition, many hardware errors would be logged
against the associated trunk circuits. If the facility is OK
and the error occurs again after 15 minutes, escalate this
problem.
Table 10-244.
TEST #1209 DS1 Board Loopback Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...