status audits
Issue 4 May 2002
8-305
555-233-123
Output
The following example is a display of status audits.
Audit information displays with one line of data displayed audit that has detected
an error or aborted. Audits that did not detected any errors or aborted do not
display. The output sorts in descending order, based on the sum of the values in
the
# Cycles Fixed Data
,
# Cycles Could Not Fix Data
, and
#
Cycles Audit Aborted
fields.
status audits cumulative
AUDIT STATUS INFORMATION
Start Date: 13:00 MON MAR 19 1990 # of Audit Cycles Completed: 67532
Audit # Cycles # Cycles Could # Cycles First Most Recent
Name Fixed Data Not Fix Data Audit Aborted Error Error
HTLK 0 ***** 0 03/22/10:14 06/24/16:03
CR-AUDIT 135 0 0 03/22/10:12 06/10/19:17
HU-CALLS 2 0 0 03/22/10:12 03/22/10:20
SE-CALLS 1 0 1 03/22/10:13 03/22/19:14
TTR-SID 1 0 0 05/01/02:17 05/01/02:17
CO-CALLS 1 0 0 05/01/02:16 05/01/02:16
DE-CALLS 1 0 0 03/22/10:12 03/22/10:12
TR-QUE 1 0 0 04/05/13:05 04/05/13:05
CTRK 0 1 0 03/22/10:12 03/22/10:12
AT-ADM 1 0 0 03/22/10:12 03/22/10:12
CO-ADM 1 0 0 03/22/10:13 03/22/10:13
PC-ADM 1 0 0 04/05/15:05 04/05/15:05
PRI-USR (SCH) 1 0 0 03/22/10:14 03/22/10:14
Command successfully completed
status audits peak-hour
AUDIT STATUS INFORMATION
Start Date: 10:00 MON MAR 22 1990 # of Audit Cycles Completed: 25
Audit # Cycles # Cycles Could # Cycles
Name Fixed Data Not Fix Data Audit Aborted
HTLK 0 25 0
HU-CALLS 2 0 0
CR-AUDIT 1 0 0
DE-CALLS 1 0 0
CTRK 0 1 0
AT-ADM 1 0 0
CO-ADM 1 0 0
SE-CALLS 0 0 1
PRI-USR (SCH) 1 0 0
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...