RDIG-STA (Remote Digital Station)
Issue 4 May 2002
10-1443
555-233-123
RDIG-STA (Remote Digital Station)
A per-port instance of this maintenance object (RDIG-STA) is used to maintain the
circuitry associated with a port which has been translated as a digital station (or
DCP Console). The combo blade circuit board has the capability of having 24
instances of this type of maintenance object.
Remote Digital Station maintenance software provides maintenance for a port
administered as a digital station on the circuit pack. This strategy covers the
in-line errors log, initialization tests, periodic tests, craft-demanded tests, and
alarm resolution and escalation. Each port, translated as a digital station on a
digital line board, is running as a separate maintenance object (RDIG-STA) of this
type. Fault conditions discovered on one maintenance object may or may not
indicate faults on other maintenance objects of the same type.
Maintenance testing for the port circuitry on the combo blade circuit packs is
handled by on-board firmware and SPE (switch) controlled tests. Maintenance
software queries the firmware for error and alarm information, status, and test
results. Firmware automatically reports in-line error conditions, which results in
SPE-controlled testing.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
UU is the universal cabinet number (1 for PPN, 2 or 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
RDIG-STA
MINOR
test station UUCSSpp l
Remote Digital
Station
RDIG-STA
WARNING
test station UUCSSpp sh
Remote Digital
Station
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...