Maintenance Object Repair Procedures
555-233-123
10-1648
Issue 4 May 2002
44
FAIL
The update files, load vintages, and announcements are
different in both SPEs. The Active SPE has the most current
update file and announcements.
45
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active SPE
has the most current update file, translations, and
announcements.
46
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active SPE
has the most current update file and announcements, and the
Standby SPE has the most current translations.
1. Follow the procedures for Error Code 4 to get the correct
load vintage. Be sure to save announcements. After
running test tape long , check for Error Code #32 or #64.
Follow the recovery procedure under the applicable error
code.
48
FAIL
The update files and announcements are different in both
SPEs. The Active SPE has the most current update file, and
the Standby SPE has the most current announcements.
1. Follow the procedures for Error Code 40.
49
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most current
update file and translations, and the Standby SPE has the
most current announcements.
50
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most current
update file, and the Standby SPE has the most current
translations and announcements.
1. Follow the procedures for Error Code #41.
Table 10-607.
TEST #421 Tape Data Consistency Check Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...