status data-module
Issue 4 May 2002
8-359
555-233-123
Output
For the following output example, the command that was entered is “status
data-module 301".
Field descriptions
Data Ext/Sta Ext
for Stn DM
The data module extension number. The DTDM is an
exception: the connected station extension is shown.
Port/Channel
Number
The port location of the data module
(cabinet-carrier-slot-circuit). If the data module specified is a
data channel, the channel number is shown instead.
Service State
This entry displays the status of the data module; valid states
are:
— In-service/idle
— The data module is present but not in use.
— In-service/active
— The data module is present and is in use.
— Out-of-service
— The data module has been removed from service
— Disconnected
— The data module no longer appears to be present
CF Destination Ext
This entry displays the call forwarding destination, if any, of
the station.
Maintenance Busy?
Whether maintenance is testing the object, “yes” or “no”.
Connected Ports
Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).
status data-module 301
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 301 Service State: out-of-service
Port/Channel Number: 01C1103 Maintenance Busy? no
CF Destination Ext:
Connected Ports:
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...