BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 4 May 2002
10-281
555-233-123
2000
ABORT
Response to the test was not received from the BRI-LINE
circuit pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit
pack if the other ports are not in use. Reset the circuit
pack by issuing the busyout board PCSS and the reset
board PCSS commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2103
ABORT
The system could not make the conference connection for the
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1, 2
FAIL
As stated previously, this test runs a TDM Loop Around Test
on each B-channel. This indicates that the loop around failed
on one of the channels. Error Code 1 indicates that the TDM
Loop Around Test failed on B1. Error Code 2 indicates that
the TDM Loop Around Test failed on B2.
7, 8
FAIL
As stated previously, this test runs a Conference Circuit Test
on each B-channel. A failure here indicates that one of these
conference tests failed; Error Code 7 means that the test
failed on B1; Error Code 8 means that the test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack
if the other ports on the circuit pack are not in use. Reset
the circuit pack by issuing the busyout board PCSS and
the reset board PCSS commands.
2. If the test fails again, replace the circuit pack.
PASS
The BRI Port Local TDM Loop Around Test has passed.
Table 10-111.
TEST #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...