ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 4 May 2002
10-255
555-233-123
2100
ABORT
Could not allocate required system resources.
2302
ABORT
Inconsistent uplink message from the ATM-TRK circuit pack.
2500
ABORT
Internal system error
Retry the command up to 5 times at 1-minute intervals.
2752
ABORT
Circuit pack not a TN2305A/2306A.
XYZ
FAIL
There is at least one bad DSP on the board. The X value
indicates the number of bad talker DSPs, Y indicates the number
of bad listener DSPs and Z indicates the number of bad echo
canceler DSPs.
Test the Active Tone-Clock on the port network that contains the
ATM-TRK circuit pack for dial-tone. Repair as needed.
Repeat the short test on the ATM-TRK circuit pack.
If the test continues to fail, check for service-affecting MINOR
alarms. If a MINOR alarm is raised for Error Type 2817 or 1818,
replace the circuit pack.
If a WARNING alarm is raised, this is a non-service-affecting
error, and the circuit pack can still process calls.
XY8
PASS
The test passed for some or all DSPs. XY8 indicates the number
of talker, listener, and echo-canceler DSPs for which the test
passed (the rest of the DSPs were skipped). The X value
indicates the number of good talker DSPs, Y indicates the
number of good listener DSPs and Z indicates the number of
good echo canceler DSPs.
0
NO
BOARD
No board detected.
Check the Error Log for wrong board Error 125 (wrong board) or
Error 131 (no board). Replace or insert the circuit pack if
necessary.
Check that the board is properly translated and inserted.
If Error 1538 (hyperactivity) is listed in the Error Log, and run
reset board UUCSS.
Run the test again, and, if it fails, replace the ATM-TRK circuit
pack.
Retest.
Table 10-104.
ATM Board DSP Test (#1293) — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...