Maintenance Object Repair Procedures
555-233-123
10-1824
Issue 4 May 2002
1147
ABORT
The ADMTSC is being torn down.
1. Issue the status tsc-administered command at 1-minute
intervals a maximum of three times.
2. If ADMTSC is still down, disable and enable the ADM
TSC via the change sig-group <group> command.
NOTE: To disable the ADMTSC, display the
(administration) Signaling Group Form via change
sig-group <group> where <group> refers to the number
of the signaling group under which the suspect TSC is
administered. Change the Enable field to "n." To enable
the ADMTSC, change the "Enable" field to "y."
3. If the ADMTSC is still down, check the other nodes in the
network. If the ADMTSC is still down, escalate the
problem.
1148
ABORT
The ADMTSC is enabled, but inactive (near-end).
1. Disable and enable the ADMTSC.
2. Reissue the test tsc-administered command.
3. If the ADMTSC is still inactive, check the other nodes in
the network.
1149
ABORT
The ADMTSC is disabled.
1. Enable the TSC, and see if the status indicates "active."
2. Reissue the test tsc-administered command.
3. If the TSC still disabled, remove the ADMTSC from the
system.
1181
ABORT
Ran out of ADMTSC resources.
1. Reissue the test tsc-administered command at
1-minute intervals a maximum of three times.
1182
ABORT
The BX.25 link is down at the gateway.
1. Disable the ADMTSC.
2. Check the status of the gateway link via status link
link-no.
3. Once the gateway link indicates an "in-service" state,
enable the Administered TSC.
4. Reissue the test tsc-administered command.
Table 10-663.
TEST #604 TSC Heartbeat Inquiry Test
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...