
Maintenance Object Repair Procedures
555-233-123
10-594
Issue 4 May 2002
Table 10-221.
TEST #314 DS1 CO Dial Tone Seizure Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call. Use the status trunk
command to determine when the port is available for testing.
1004
ABORT
The port has been seized by a user for a valid call. Use the
status trunk command to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1005
ABORT
Test failed due to incompatible configuration administered in
trunk group form.
1. Look at the trunk group administration form and see
whether the trunk is incoming only, port 24 on a DS1
Interface with common control channel signaling, or an
automatic CO type such as FX. Under any of these
conditions this is a normal abort.
1018
ABORT
Test has been disabled via administration.
1. Verify that the ‘‘Maintenance Tests’’ field on the Trunk
Group Form is set to ‘‘n.’’ To enable the test, issue the
change trunk-group x command where ‘‘x’’ equals the
number of the trunk group to be tested. Then change the
entry in the ‘‘Maintenance Tests’’ field on the form to ‘‘y.’’
2. Repeat the test.
1020
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If
present, refer to the UDS1-BD (DS1/UDS1 Trunk Circuit
Pack) Maintenance documentation.
2. Retry the command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...