Maintenance Object Repair Procedures
555-233-123
10-1676
Issue 4 May 2002
2000
ABORT
Response to the test was not received from the BRI-LINE
circuit pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit
pack with busyout board PCSS and reset board PCSS
if the other ports on the board are not in use.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2103
ABORT
The system could not make the conference connection for the
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1, 2
FAIL
The TDM Looparound failed on one of the channels.
■
Error Code 1 — TDM Loop Around Test failed on
B1.
■
Error Code 2 — TDM Loop Around Test failed on
B2.
7, 8
FAIL
The Conference Circuit Tests failed on a B-channel.
■
Error Code 7 — test failed on B1
■
Error Code 8 — test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack
with busyout board PCSS and reset board PCSS if the
other ports on the board are not in use.
2. If the test fails again, replace the circuit pack.
PASS
The BRI Port Local TDM Loop Around Test passed.
Table 10-615.
TEST #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...