ABORT
Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error Type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is
out of service and one or more of the following symptoms may
be exhibited.
1. The UDS1-BD tests (such as Test #138 and Test #139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. A busyout or a release command has no affect on the test
results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will
try to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the UDS1 interface
circuit pack is restored to normal operation. All of the
trunks for the UDS1 interface circuit pack are then
returned to the in service state. Hyperactivity is often
caused by the associated facility. In such a case, faults
(such as slips, misframes, or blue alarms) would be
entered in the error log. In addition, many hardware
errors would be logged against the associated trunk
circuits. If the facility is OK and the error occurs again
after 15 minutes, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
FAIL
UDS1 Interface circuit pack failed the CSU Repeater Loopback
Test.
1. Retry the test ds1-loop UUCSS ds1/csu-loopback-tests
command.
2. If the RLB test continues to fail, and the CSU Equipment
Loopback Test (#1210) passed, then replace the CSU
Module/T1 Sync Splitter.
Table 10-684.
TEST #1211 CSU Repeater Loopback Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...