ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 4 May 2002
10-245
555-233-123
Table 10-98. ATM Board Reset (#1256)
Error
Code
Test
Result
Description/Recommendation
1005
ABORT
Wrong circuit pack configuration to run this test. The ATM CES
Trunk Interface circuit pack provides timing for the system and
cannot be reset without major system disruptions.
Set synchronization to another ATM CES trunk circuit pack or to
the Tone-Clock circuit pack and test again.
1015
ABORT
Test cannot be run because the ATM-TRK circuit pack has not
been busied out.
Busyout out the circuit pack (busyout board UUCSS).
Repeat the test (test board UUCSS long).
None
ABORT
Could not allocate the required system resources
Retry the command up to 5 times at 1-minute intervals.
If the test continues to abort escalate the problem.
2000
ABORT
Sanity test timed out.
Wait 5 minutes. Then see if ATM-TRK circuit pack is visible to the
system by running list configuration all.
If the ATM-TRK circuit pack is visible (list configuration all), run
the test again, and escalate if the problem recurs.
If the ATM-TRK circuit pack is not visible to the system (list
configuration all), re-seat the ATM-TRK circuit pack, and retest.
If the ATM-TRK circuit pack is still not recognized by the system,
replace the board.
2100
ABORT
Could not allocate required system resources
Retry the command up to 5 times at 1-minute intervals.
2500
ABORT
Internal system error
Try to reset the circuit pack (reset board UUCSS).
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...