Maintenance Object Repair Procedures
555-233-123
10-104
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
Either a system allocation to get information about the port or
to put the port into a service state failed or the attempt to put
the port in connection with a tone source failed (this could be a
tone-clock problem). The tone-clock and tone detectors could
be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5
times.
7
FAIL
The conference test or the noise test failed. This could cause
noisy or unreliable connections, or users calling this port may
hear an echo. The problem can also be off-board, as described
below.
13
The reflective loop around with gain set to low and the
600-ohm balance failed. This will cause noisy or unreliable
connections.
14
The reflective loop around test (with the gain set to high, using
RC balance) failed. This could cause noisy or unreliable
connections. The problem can also be off-board, as described
below.
15
The nonreflective loop around test failed. This could cause
noisy or unreliable connections, or users calling this port may
hear an echo. The problem can also be off-board, as described
below.
More information continues on the next page.
Table 10-35.
TEST #47 Loop Around and Conference Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...