Maintenance Object Repair Procedures
555-233-123
10-1244
Issue 4 May 2002
13
ABORT
The TN765 circuit pack has not been reset yet or is currently
being reset.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If test continues to abort with error code 13, then check status
of all BX.25 and/or ISDN-PRI links on this TN765 via the
status link lnk-no command. If all links are not in-service,
then reset the TN765 using the test interface PCS long
command.
3. If the TN765 fails to reset, refer to the PI-SCI section of this
manual.
4. Else, retry the test link lnk-no command.
5. If the test still aborts with error code 13 or from step 2, and
some links are in-service and a error code is still present,
escalate the problem.
16
80
84
85
93
94
102
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, then reset the PI-BD via the test
interface PCS long command.
3. If problem still exists, replace the TN765 circuit pack.
1005
ABORT
The test is not applicable if the EIA port is being used as part of
the link.
12
FAIL
PI-BD reported that Loop Around Test failed.
1. Retry the test.
2. If Test #182 fails, see section for Test #182 first.
3. If Test #182 passes and Test #183 continues to fail, replace
either the TN754 or TN784 Digital Line or the TN722 or
TN767 DS1 Interface circuit pack.
4. If Test #183 still fails, replace the TN765 PI-BD.
PASS
The loop around from the TN765 PI-BD to the Digital Line or DS1
Interface circuit pack and then back to the PI-BD passed.
Table 10-462.
TEST #183 TDM Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...