Maintenance Object Repair Procedures
555-233-123
10-1572
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error may not cause a Switch Control alarm if Error Type 769 is also
present since this error may actually be caused by the loss of clock signals
and not by a Switch Control failure.
Table 10-581.
SW-CTL Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test network-control a/b sh r 1
1
Any
Control Channel
Test (#94)
MAJOR
ON
test network-control a/b r 3
2 (a)
Control Channel
Test (#94)
MAJOR
ON
test network control a/b r 3
257 (b)
0
1
None
513 (c)
Time of Day Clock
Test (#95)
MINOR
ON
test network-control a/b l r 3
769 (d)
Any
None
1025
Switch Control
Loop Around Test
(#92)
MAJOR
ON
test network-control a/b r 3
1281
(e)
Any
None
1537
Switch Control
Reset Test #93
MAJOR
ON
test network-control a/b l r 2
1793 (f)
Any
None
2817
MCD Loop Around
Test (#324)
MAJOR
ON
test network-control a/b r 2
3073
MCD Memory Test
(#325)
MAJOR
ON
test network-control a/b r 3
3329
(g)
None
MAJOR
ON
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...