Maintenance Object Repair Procedures
555-233-123
10-1402
Issue 4 May 2002
c. Aux Data of 100 is an LMM Flash Checksum initialization failure.
d. There are Functional Memory Test errors against the Processor circuit
pack. This test is run only on the Standby SPE in a High or Critical
Reliability system. On other systems or on the Active SPE, the test is run
only via a reset system 4 command or a reset system 5 command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate errors in the order in which they are presented in the table that
follows when you are inspecting errors in the system. By clearing error codes
associated with the Read All Memory Test, for example, you may also clear errors
generated from other tests in the testing sequence.
Notes:
a. Refer to PROCR (TN2404/TN790 RISC Processor) Maintenance
documentation for a description of these tests.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Processor Cache Test (#895)(a)
X
ND
Processor Cache Audit (#896)(a)
X
X
ND
Processor Bus Time-out Exception Test (#82)(a)
X
X
ND
Processor BOOTPROM Checksum Test (#897)(a)
X
X
ND
Processor Write Buffer Test (#900)(a)
X
X
ND
Memory Burst Read Test (#908)
X
X
ND
Read All Memory Test (#85)
X
ND
Memory Parity Error Detection Test (#87)
X
X
ND
Flash Memory Checksum Test (#86)
X
ND
Memory Functional Test (#332) (b)
X
D
MTP Outpulse Relay Test (#102) (c)
X
X
ND
MTP External Modem Present Test (#230) (c)
X
X
ND
MTP Analog Loop Around Test (#103) (c)
X
X
ND
MTP Sanity Handshake Test (#106) (c)
X
X
ND
MTP SAT Loop Around Test (#228) (c)
X
X
ND
MTP Aux Loop Around Test (#229) (c)
X
X
ND
MTP Reset Test (#101) (c)
X
D
MTP Dual Port Ram Test (#104) (c)
X
D
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...