RDIG-STA (Remote Digital Station)
Issue 4 May 2002
10-1449
555-233-123
Notes:
a. Error type - 1; with Aux Data of 40987 — could be caused by a noisy port
or link. This is an off-board problem detected by the port circuit. Check for
defective wiring, a defective voice terminal, or move the voice terminal
closer to the switch (in terms of feet of wire from the jack to the switch). If
the problem persists, replace the circuit pack. Once the problem has been
resolved, the alarm disappears after a predetermined amount of time.
Error Type - 1; with Aux Data of 1 to 20 — occurs when at least 15
off-board problems have been detected with the link to the terminal. When
an error with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for defective wiring, a defective voice
terminal, or move the voice terminal closer to the switch (in terms of feet of
wire from the jack to the switch). If the problem persists, replace the circuit
pack. Once the problem has been resolved, the alarm disappears after a
predetermined amount of time.
b. Error Type - 18 — is logged when the port in question is busied out by
maintenance personnel. Make sure the port is released from busyout by
the release port UUCSS pp/PCSSpp command.
c. Error Type - 257 — indicates problems transmitting to the voice terminal,
which can be caused by defective wiring. Defective wiring can cause
varying degrees of problems on different types of sets.
d. Error Type - 513 — is the result of an ID Request failure to respond to the
digital endpoint audit.
1537 (h)
40968
None
WARNING
OFF
2304 (i)
None
2305 (j)
32770,
40967
None
2817 (k)
Hyperactive
MINOR
OFF
3840 (l)
40965,
40989
None
3841 (m)
41029
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-549.
Digital Line Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...