
Maintenance Object Repair Procedures
555-233-123
10-1978
Issue 4 May 2002
Table 10-710.
TEST #1104 VC DSPPT Local TDM Loopback Test
Error
Code
Test
Result
Description/Recommendation
1000
1001
ABORT
System resources required to run this test are not available,
or the port is busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of
5 times.
1002
ABORT
The system could not allocate time slots for the test. The
traffic load on the system is very high, or time slots may be
out-of-service due to TDM-BUS errors. Refer to “TDM-BUS”
to diagnose TDM Bus errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at 1-minute
intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a Tone Detector for the test.
The system is oversized for the number of Tone Detectors
present, or some Tone Detectors are out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the test at 1-minute
intervals.
1004
ABORT
The port is seized by a user for a valid call. Use the status
station command for the station associated with this port
and determine if the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2000
ABORT
Response to the test was not received from the VC-BD circuit
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the port
by using the busyout port PCSSpp and reset port
PCSSpp commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of
5 times.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of
5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...