Maintenance Object Repair Procedures
555-233-123
10-546
Issue 4 May 2002
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested
for on-/off-hook detection, battery shutdown, and battery reversal (WINK)
capabilities.
Table 10-199.
TEST #35 Port Diagnostic Test
Error
Code
Test
Result
Description/Recommendation
ABORT
System resources required to run this test were not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test were not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no
calls), then check the error log for error type 513 (refer to
the Error Log table for a description of this error and
required actions). The port may be locked up.
2. If the port status is idle, busyout and release the trunk,
and then retry the command at 1-minute intervals for a
maximum of 5 times.
3. If the test continues to abort, check for wiring errors
toward the CO which may cause the trunk to lock up.
4. If the wiring is OK and the test continues to abort, replace
the TN753.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...