PROCR (TN2404/TN790 RISC Processor Circuit Pack)
Issue 4 May 2002
10-1429
555-233-123
Processor Cache Test (#895)
This test is a nondestructive test. This test overwrites the contents in the
Instruction and Data Caches, requiring them to be refilled during normal
execution.
This test verifies that the Processor Instruction and Data Caches are functional.
Some errors in the caches will simply reduce performance by forcing instructions
or data to be read from memory more often than would normally be necessary. In
any case, cache problems are serious and the Processor circuit pack must be
replaced as soon as possible if they are detected.
Table 10-540.
Test #895 Processor Cache Test
Error
Code
Test
Result
Description/Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
2500
ABORT
Internal system error
1. Retry the command.
FAIL
The Processor cache is not functioning correctly.
1. Replace the Processor circuit pack immediately.
NOTE:
If you replace the Processor circuit pack, you
need to obtain a new license file.
PASS
The cache portion of the Processor circuit pack is operating
correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...