EMG-XFER
Issue 4 May 2002
10-733
555-233-123
EMG-XFER
Emergency Transfer (SCC Cabinets)
The system provides the ability to cut designated analog phones through to CO
trunks if the switch cannot provide even minimal phone service. This ability is
known as Emergency Transfer. Each port network PPN and EPN can have a
separate Emergency Transfer capability. The EMG-XFER MO tracks the control of
Emergency Transfer. There is one EMG-XFER MO for each port network.
Emergency Transfer can be controlled by the system or can be manually
controlled within each port network via the Emergency Transfer switch(es) which
is (are) located on the Processor circuit pack and the EPN Maintenance circuit
pack. If the Emergency Transfer switch or switches in a high or critical reliability
system on the Processor circuit pack or EPN Maintenance circuit pack are in a
manual position, the system cannot change the state of Emergency Transfer
within that port network. A manual ON position (to the right) generates a Major
alarm. A manual OFF position (to the left) generates a Warning alarm. Unless a
technician is currently working on the system, the switches should be left in the
auto position ().
On a high or critical reliability system, the switches on BOTH Processor circuit
packs must be in the ON position to manually invoke Emergency Transfer.
However, if EITHER switch is in the OFF position, Emergency Transfer cannot be
controlled by the system and is in the manual OFF state. The status system
system technician command displays the current state of the Emergency Transfer
switches in the system. Valid states for the switches are: manual ON, manual
OFF, auto ON (the switch is in the auto position and the system has invoked
Emergency Transfer), or (the switch is in the auto position and the system has
invoked Emergency Transfer), or auto OFF (the switch is in the auto position and
the system has not invoked Emergency Transfer).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
Where P is an appropriate port network number determined via the PORT field from the
Alarm or Error Log.
Full Name of MO
EMG-XFER
MAJOR
test environment P
Emergency Transfer
EMG-XFER
WARNING
test environment P
Emergency Transfer
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...