Maintenance Object Repair Procedures
555-233-123
10-1092
Issue 4 May 2002
Read All Memory Test (#85)
This test is a nondestructive test. The test reads every memory location in
memory and writes it back. A failure of this test indicates a failure in the Processor
or Memory circuit pack.
Table 10-412.
TEST #85 Read All Memory Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1
FAIL
If the system can still provide service, this indicates that the
Processor circuit pack or Memory has a problem, but can still
function. The error code “1” indicates that MEM-BD 1 is failing
the test.
1. Replace the PROCR (Processor circuit pack). (Note that if
you replace the Processor circuit pack, you need to obtain
a new license file.)
!
WARNING:
If the Processor circuit pack must be replaced, and if
there is a blank in the Expansion Memory circuit pack slot
(that is, in the slot immediately to the right of the
Processor circuit pack), remove the blank before
removing the circuit pack. Otherwise, the circuit pack
and/or the two connectors that are used to connect the
Expansion Memory circuit pack (if available) might
become damaged.
PASS
The Memory is healthy.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...