Maintenance Object Repair Procedures
555-233-123
10-718
Issue 4 May 2002
Inter-Duplication Interface Circuit Pack Loop
Back Test (#280)
This test loops back data through the UART used to communicate with the other
Duplication Interface circuit pack. The data is generated by the Duplication
Interface circuit pack processor and is looped through the UART. The test is done
entirely on the Duplication Interface circuit pack. The test passes if the data sent
matches the data received. This test does not check the physical serial channel
that is printed on the backplane or carried by the ICC.
Table 10-268.
TEST #280 Inter-Duplication Interface Circuit Pack Loop Back Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The tested UART on the Duplication Interface circuit pack is
defective.
1. Replace the Duplication Interface circuit pack.
2. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack B has failed to reply to
handshaking either from Duplication Interface circuit pack A.
1. Refer to NO BOARD description for the Duplication
Interface Circuit Pack Status Query Test (#315).
PASS
The Inter-DUPINT UART on the tested Duplication Interface
circuit pack is good.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...