Maintenance Object Repair Procedures
555-233-123
10-710
Issue 4 May 2002
Duplication Interface Circuit Pack Invalid
Message Query Test (#272)
The Duplication Interface Circuit Pack Invalid Message Query Test sets the
threshold for the number of bad checksum errors the Duplication Interface circuit
pack detects before reporting the problem to maintenance and queries the
Duplication Interface circuit pack for the number of checksum errors detected.
The error threshold is set to 10. The query causes Duplication Interface circuit
pack firmware to clear its bad checksum error counter. This test is run on both
circuit packs, but has little meaning on Duplication Interface circuit pack B and
should always pass.
Table 10-262.
TEST #272 Duplication Interface Circuit Pack
Invalid Message Query Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The Duplication Interface circuit pack is receiving an abnormal
number of corrupted messages.
1. First investigate other Duplication Interface circuit pack
tests that are not passing.
2. If this is the only test that fails, investigate and resolve all
alarms against PR-MAINT (Maintenance/Tape Processor).
3. Rerun the test. If the test still fails, follow the procedures
for replacing Common Control circuit packs and replace
the Duplication Interface circuit pack.
4. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack has failed to handshake
with either the active Maintenance/Tape Processor (in the case
of Duplication Interface circuit pack A) or the Duplication
Interface circuit pack A (in the case of Duplication Interface
circuit pack B).
1. Refer to NO BOARD description for the Duplication
Interface Circuit Pack Status Query Test (#315).
PASS
The Duplication Interface circuit pack has not received any bad
messages from either Maintenance/Tape Processor or the
other Duplication Interface circuit pack. All serial links are
operating fine.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...