Maintenance Object Repair Procedures
555-233-123
10-196
Issue 4 May 2002
Table 10-66.
ATM-BCH alarms by service state
Service state
Alarm
1
1
ATM-BCH alarms; alarms against other maintenance objects may also be present.
Possible cause
Possible solution
Out-of-Service/NE
Warning
Trunk busied out
Release the port (release trunk
grp#/mbr#).
Minor
NPE Crosstalk Test
(#6) failed
Replace ATM circuit pack.
None
ATM circuit pack lost
signal or there is a
circuit pack problem.
Install circuit pack or cable. Check
circuit pack using procedures in
ATM-BCH. Check far-end switch
status.
Out-of-Service/FE
Warning
Unadministered far-end
Administer the corresponding trunk
on the far-end switch.
Warning
Far-end busied out
Check the status of the far-end
switch.
Pending/In-Service
Pending/Maint
None
Maintenance message
timed out waiting for
reply
Wait 2 minutes after the pending
state clears, and check the service
state.
Maint/NE
None
ISDN test call in
progress (test trunk
long)
Wait for the test to finish and recheck.
None
System link busied out
Check link status. Run release link
link#.
Maint/FE
Warning
Signaling channel down
for over 90 sec.
See
ATM-SGRP
or
ATM-DCH
.
Warning
Repeated lack of
response to messages
sent to the far end
Wait. Maintenance software resends
messages periodically. Or run test
trunk grp#/mb# or test
signaling-grp grp#.
Warning
The far-end trunk is
being tested.
Check status of the far-end switch.
Wait for testing to finish.
In-Service
None
Normal operating state
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...