Maintenance Object Repair Procedures
555-233-123
10-1352
Issue 4 May 2002
PPP-PT (Control LAN Packet/Port)
The TN799 Control LAN (CLAN) packet port circuit pack provides TCP/IP
connection to adjuncts applications such as CMS, Intuity, and DCS Networking.
The CLAN circuit pack has 1-10baseT Ethernet connection and up to 16 DS0
physical interfaces for PPP connections. Multiple CLAN circuit packs in a system
gives additional TCP/IP capacity.
A remote socket control link (RSCL) links the CLAN and the SPE to pass call
control and other management information. Since one link serves all the ports on
the circuit pack, maintenance of the RSCL is part of the CLAN circuit pack
maintenance.
NOTE:
The CLAN TN799 circuit pack combines the functions of the PGATE and PI
circuit packs into one circuit pack. The PGATE or PI can be used with the
CLAN to create an X.25 to TCP/IP bridge for adjunct and DCS connectivity.
Control LAN Congestion Controls
The switch activates congestion controls on CLAN when it detects buffers
exceeding the threshold. The switch releases the congestion controls when the
CLAN reports that its buffer level has returned to normal levels.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
UU is the universal cabinet number (1 for PPN, 2 or 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
PPP-PT
MAJOR
test port UUCSSpp long
PPP Port Maintenance
PPP-PT
MINOR
test port UUCSSpp long
PPP Port Maintenance
PPP-PT
WARNING
test port UUCSSpp
PPP Port Maintenance
If congestion:
Then the switch:
Persists for a 14-minute interval
Raises MINOR alarm
Exhausts buffers
Raises MINOR alarm
Ceases for 12 minutes
Retires MINOR alarm
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...